Start Capacitor Vs Run Capacitor: 3 Important Facts

Home > Resources > Start Capacitor Vs Run Capacitor: 3 Important Facts

Start Capacitor Vs Run Capacitor: 3 Important Facts

Start Capacitor Vs Run Capacitor: 3 Important Facts Apr. 06, 2023

Start Capacitor Vs Run Capacitor: 3 Important Facts -

Start capacitor and run capacitor, both are motor capacitor, both are used for different purpose in the motor operation. Construction of both the capacitor is same, let’s discuss Start Capacitor vs Run Capacitor.

 

 

Start CapacitorRun CapacitorThey are used for starting the motor. They are used for providing continuous power to the motor. Small duty cycle.Long duty cycle.Higher Capacitance rating (70-120 micro Farad)Lower Capacitance rating (7-70 micro Farad)Remain connected to the circuit for short period of time.Remain connected to the circuit for long period of time.The start capacitor is used during the startup phase of the motor and gets disconnected from the circuit when the motor reaches its predetermined speed, which is 75% of the maximum speed of the motor. Run Capacitor stays directly linked with the auxiliary coil even after the starting capacitor is disconnected (or deactivated) from the circuitry. The run capacitor remains constantly charged while providing a controlled contiguous (or continuous) power to the motor. 

 

 

Can I use a Run Capacitor as a start capacitor?

The purpose of starting capacitor is to lag the current in a gallery winding during the starting operation of the motor, and it gets disconnected from the circuit when the router reaches its predetermined speed.

The run capacitor can be operated as a start capacitor, whereas the start cannot be implement as a Run capacitor. To start the motor or develop high torque across the motor, a high capacitance value is required to show the run capacitor array (two or more capacitors are connected in cascade) can be connected.

 

 

 

 

The capacitor value of the run capacitor is very much smaller than that of the start capacitor; a single running capacitor will not be able to start the motor as it cannot provide enough torque to the motor. There won’t be any problem (or drawback) with the run capacitor to start the motor, but the starting (or beginning) character may not be up to mark, and the motor may take a higher(or intense) starting current with lower torque.

 

 

What happens when a Run Capacitor goes bad ?

Capacitor failure can be of two types. Catastrophic failure is generally caused by the motor starting circuit being engaged for too long. The top of the starting capacitor has been blown off, and the inside has been slightly or fully ejected. The capacitor may be just raptured pressure relief blister.

 

 

 

 

 

The motor can display various problems if a run capacitor fails, including not starting vibrating, overheating, slow start, or motor buzzing. The motor will not have an uniform electric field that will cause the router(or root) to hesitate at irregular spots. A bad Run capacitor will cause the motor to become noisy, have high energy consumption, drop performance, overheating, etc.

 

 

 

 

What is the purpose of a Starting Capacitor ?

The start capacitor is come up with in auxiliary (or start) windings of the motor. The capacitance of a start capacitor is much elevated than that of a run capacitor.

The objective of the start capacitor is to provide enough torque to start (or energize) the motor, and it gets disconnected (or deactivated) from the circuit after the motor reaches a predetermined  (or predestined) speed. Without a start capacitor when the voltage has applied to motor, the motor will generate (or give rise to) a humming sound. The capacitance range of a start capacitor is between 70 to 120 micro Farad.

 

Start capacitor increases motor starting torque and allows the motor to be cycled off and on rapidly. The start capacitor is designed in such a way that it is used just for a small time period. They can’t stay energized for longer.

How to tell AC capacitor is bad ?

AC capacitor is an integral part(or component) of an outdoor condensing unit of an air conditioner(or AC) or heat pump. AC capacitor provides sufficient power to the motor, which steers the air conditioning system.

 

 

 

 

Sign of bad AC capacitor:

Smoke or burning smell from the exterior air conditioner component

Air conditioning is not bring about cold air even after a long time of operation

Humming noise from the air conditioner

Old HVAC system

AC terms off on its own or on random

AC doesn’t start working immediately after turning on

High energy consumption causes high energy bills without expectation

Effect of failed AC capacitor:

Overheated system circuit

Short-circuiting in the AC (or cooling system).

Power Rushes or Surges.

Electrical discharge or Lightning strikes.

Intensely peak outdoor temperature

How do start and run capacitors differ?

Something went wrong. Wait a moment and try again.

HVAC Start and Run Capacitor Explained and Replacement – HVAC How To


Capacitors are used in HVAC to help electrical motors to start and keep running smoothly.

They are low-cost components that come in multiple packages, shapes, and sizes.

What are Start Run Capacitors?

A Start capacitor helps a motor start to turn, while a Run capacitor helps it to operate more smoothly.

Motors used in HVAC, such as the condensing fan motors or blower fan motors, sometimes need help to start moving and to stay running at a steady pace, with no heavy up and down spikes.

To do this, HVAC units use what are called Start and Run capacitors which can add more amps or smooth out voltage spikes.

Start Capacitor vs. Run Capacitor?

A Start Capacitor holds a charge to start a motor moving.

A Run Capacitor keeps a motor running smoothly with no big up and down spikes.

Start Run capacitors are usually a single capacitor but can be separate

Not all motors will have a start or run capacitor; some can start and run by themselves.

Capacitors in HVAC can be separated with two capacitors or can be in a single package.

When they are separate, they are called “Single,” and when they are combined into one package, they are called “Dual Round.”
 
Example Dual Round HVAC Capacitor

 
Example Single HVAC Oval Capacitor

The Dual Round Capacitors are engineers trying to save on space and cost.

They could have put two separate capacitors in an HVAC unit but combined them into one package.
 

Example Dual Round HVAC Capacitor Wiring Diagram


A dual capacitor will have one leg to start the compressor (Labeled Herm) and another leg to start the condensing fan motor (Labeled Fan).

The third leg on a dual capacitor is a shared common leg (Labeled “C”).

How Do Capacitors Work In an HVAC System?

A Start or Run Capacitor can be combined into one capacitor called a Dual Capacitor with three leads but can be split between two separate capacitors.

The Start Capacitor gives a fan motor the torque it needs to start spinning then stops, while the Run capacitor stays on, giving the motor extra torque when needed.

If the Start Capacitor fails, the motor will most likely not turn on. If a Run capacitor goes bad, then a motor can turn on, but the running amperage will be higher than normal, causing the motor to run hot and have a short life expectancy.

After replacing a bad Condensing Fan Motor, a new Start Run Capacitor should always be installed.

A Dual Capacitor has three connections HERM, FAN, and COM.

HERM, connects to the Hermetically Sealed Compressor.

FAN, connects to the Condenser Fan Motor.

COM, connects to the Contactor and provides power to the Capacitor.

If the unit has two capacitors, one is the Run Capacitor, and the other is the Start Capacitor. Keep in mind the compressor also often needs a capacitor which will be HERM (compressor).

How to Buy a New HVAC Capacitor

A new Capacitor should always be installed with a new motor. A capacitor can be bought at an HVAC supply company; there are usually at least a few even in a small town; also, online, Amazon or eBay is a good place to look.

Here are two common capacitors, the one on the left is a Dual Round Capacitor, while the one on the right is a Run Oval capacitor.

The Dual Capacitor is nothing more than two capacitors in the same housing, while the Run oval is a single capacitor, and an HVAC system will usually have two.

Capacitors are measured by the Microfarad, sometimes shown by the letters “uf” and Voltage. In any HVAC unit, the capacitor must match the motor.

The voltage can go higher if necessary but never lower, while the MFD (uf) should always be the same. In the picture, this is a Dual Run Capacitor and reads 55+5 MFD (uf) 440 VAC. The larger number 55 MFD is for the compressor, while the lower number 5 MFD (uf) is for the fan motor.

The lower number is always going to be for the fan motor. Then the voltage is 440 Volts AC.

(The + -5 after the MFD is how much it the capacitor tolerance is rated to go up or down.)

To order a replacement for this capacitor, it would be 55+5 MFD (uf) and 440 volts AC Dual Run Capacitor.

Example HVAC Dual Capacitor On Amazon
MAXRUN 55+5 MFD uf 370 or 440 Volt VAC Round Dual Run Capacitor for Air Conditioner or Heat Pump Condenser – 55/5 Microfarad Runs AC Motor and Fan – 5 Year Warranty

 

Testing an HVAC Capacitor

Testing an HVAC capacitor is done with an HVAC multi-meter; the multi-meter must be cable of reading the range that an HVAC capacitor can have. Many small electronic meters do not have this range.
Here I am using the Fieldpiece HS36 multi-meter with an Amp clamp.

This test is being done on a Dual Run Capacitor 55+5 MFD (uf). The multi-meter is on Farads, and the leads are on C and FAN (positive and negative do not matter). The lower number is for the fan motor, which is rated at 5 MFD (uf), and it reads 5.3 MFD (uf), so it is good. The leads C to Herm can also be read, which would be for the compressor.

To test a Run Oval Capacitor, simply touch the two leads. This one reads 4.5 MFD (uf) and is rated at 5 MFD (uf), so it is bad and needs replacing.

 

How To Replace a Start Run Capacitor


A new fan capacitor should always be installed when a new motor is installed. It is always a good idea to take a picture or write down wire coloring and connections.

(If you have two capacitors one is for the compressor and one is for the fan motor.)

Turn off the power to the HVAC unit and verify it is off with a meter.

Find the side panel where the electric is fed into the unit and remove the panel.

Locate the Stat Run Capacitor, if it is a Dual Run capacitor there will be only one. If there is two then only the fan motor capacitor will need to be replaced.

Verify the MFD and voltages, then connect the new connections from the old capacitor to the new capacitor one leg at a time to be sure the connections are correct.